Application / Description
For connections in all fields of measuring and control engineering as well as in the signal and impulse technology. UL-specifications have to be matched for products which are exported to the american market. Because of SR-PVC is used as core-insulation, suitable for insulation displacement connectors (IDC). The outer jacket is to a very large extent resistant against oils, petrol- and weather-proof as well as uv-resistant by special-pvc.
Variant data
O.D.
- approx. 5,50 mm
weight
- 45,0 kg/km
Cu-weigth
- 17,1 kg/km
skinning tool (jacket)
- 40025
skinning tool (core)
- 20300 / 30160
Construction / data
Conductor
- tinned stranded copper wire
Structure of conductor
- 7 x 0,20 mm
Cross section
- 0,22 qmm
Core-Ø
- approx. 1,15 mm
AWG
- AWG 24
number of cores
- 8
Core insulation
- Semi-Rigid-PVC
Colour sequence
Twisting
- cores in layers
Outer jacket
- Special PVC, flame retardant acc. UL-VW-1
Outer jacket colour
- black, sim. RAL 9005
Dimension
- 8 x AWG 24
Technical characteristics
Temperature range
- static: -30 °C to +105 °C
- dynamic: -15 °C to +105 °C
- *UL 2517. Per UL 2464 only +80°C
Bending radius
- > 15 x O.D.
Operating capacity (C/C)
- approx. 130 pF/m
Operating voltage
- 300 V
Testing voltage
- 1.500 V
Insulation resistance
- > 100MOHM x km at + 20°C
Conductor resistance
- max. 88,0 Ohm/km
Packaging
Rings at 100m, Reels at 500mLower and upper lengths according to availability. Special packaging on request.
Add-on information
Temperature rating per UL- Style 2464: 80°C; Style 2517: 105°C