- installation
- halogen free
- FRNC
- RoHS
- REACH
- CE
- UN/ECE R118
Application / Description
Measuring, signal-, and control-technology as as well as in EDP periphery, where safety regulations prescribe the use of halogen-free / flame-retardant cable. The pair twisting optimizes cross-talk attenuation and prevents electrical coupling within the line to a large extent. Increased interference protection as well as increased mechanical maximum stress by copper braid.
Variant data
O.D.
- approx. 12,00 mm
weight
- 225,0 kg/km
Cu-weigth
- 127,4 kg/km
skinning tool (jacket)
- 40025
skinning tool (core)
- 30155 / 30900
Construction / data
Conductor
- bare stranded copper wire
Structure of conductor
- 18 x 0,10 mm
Cross section
- 0,14 qmm
Core-Ø
- approx. 1,05 mm
number of cores
- 50
Core insulation
- PE-EVA halogen-free
Colour sequence
number of pairs
- 25
Pre-twisting
- conductors to pairs
Twisting
- pairs in layers
Overall shield
- tinned copper braid, coverage approx. 85 %, drain-wire
Outer jacket
- PE-EVA (FRNC)
Outer jacket colour
- grey sim. RAL 7001
Dimension
- 25 x 2 x 0,14 qmm
Technical characteristics
Temperature range
- static: -25 °C to +80 °C
- dynamic: -5 °C to +70 °C
Bending radius
- > 15 x O.D.
Bending radius static
- > 10 x O.D.
Bending radius dynamic
- > 15 x O.D.
Operating capacity (C/C)
- approx. 65 pF/m
Characteristic impedance
- 100 Ohm +/-10%
Operating voltage
- 350 V
Testing voltage
- 800 V
Current capacity (at +25° C)
- 1,50 A (by respectively one core per cabel is loaded)
Insulation resistance
- > 200 MOHM x km at + 20°C
Reaction to fire UN/ECE R118
- ISO 14572
Packaging
Rings at 100m, ReelsLower and upper lengths according to availability. Special packaging on request.
Add-on information
- Flame retardant acc. to IEC 60332-1-2 / 2-2
- zero halogen acc. to DIN VDE 0472 part 815 / IEC 754-1
- no acid gas emission acc. to DIN EN 60754
- low smoke emission in case of fire